ST1000LM014-1EJ164 SSHD不认盘恢复成功案例
客户:上海一客户
日期:2018.3.16
硬盘型号:ST1000LM014--1EJ164 SN:W77292D1 FW:SM16 电路板号:100705349
故障现象:硬盘通电不认盘,这种是固混盘
解决方案:收到硬盘后,接到专业的数据恢复工具PC-3000 UDMA Express上,通电检测发现,终端信息如下:
Boot 0x40M
Trans.
ALFRecorder:
ReadJournalLog
ReadJournalLog
ReadJournalLog
ReadJournalLog
ERROR: Flash Led 9C07 - Couldn't ID Flash Device
Bridge PSM Driver ID: FFFF
LbaMidWord: 9384
LbaHighWord: D798
ReadJournalLog
ReadJournalLog
ReadJournalLog
ReadJournalLog
ERROR: Flash Led 9C07 - Couldn't ID Flash Device
Bridge PSM Driver ID: FFFF
LbaMidWord: 9384
LbaHighWord: D798
Clump Parametrics:
Clump = D772
DataType = 0000
ModeFlag = 02
EraseCount = 19464A98
EraseFailCount = 01
ProgramFailCount = 02
WeakReadCount = 1F
UncorrectableECCError = 07
Clump = D772
DataType = 0000
ModeFlag = 02
EraseCount = 19464A98
EraseFailCount = 01
ProgramFailCount = 02
WeakReadCount = 1F
UncorrectableECCError = 07
---SOC PSM Command History---
Cmd#/PsmCmd Clump Offset Length LbaMid LbaLow LbaBits39To32 Options Status DestClump DestOffset
000E D772 FEB9 E674 9384 FFFF D798 A2E3 0080 ADCA B9E5
ERROR: Flash Led 9C07 - Couldn't ID Flash Device
Bridge PSM Driver ID: FFFF
LbaMidWord: 9384
LbaHighWord: D798
Cmd#/PsmCmd Clump Offset Length LbaMid LbaLow LbaBits39To32 Options Status DestClump DestOffset
000E D772 FEB9 E674 9384 FFFF D798 A2E3 0080 ADCA B9E5
ERROR: Flash Led 9C07 - Couldn't ID Flash Device
Bridge PSM Driver ID: FFFF
LbaMidWord: 9384
LbaHighWord: D798
Clump Parametrics:
Clump = D772
DataType = 0000
ModeFlag = 02
EraseCount = 19464A98
EraseFailCount = 01
ProgramFailCount = 02
WeakReadCount = 1F
UncorrectableECCError = 07
Clump = D772
DataType = 0000
ModeFlag = 02
EraseCount = 19464A98
EraseFailCount = 01
ProgramFailCount = 02
WeakReadCount = 1F
UncorrectableECCError = 07
---SOC PSM Command History---
Cmd#/PsmCmd Clump Offset Length LbaMid LbaLow LbaBits39To32 Options Status DestClump DestOffset
000E D772 FBB9 6674 9384 FFFF D798 A2E3 0080 BFCA B9E5
Cmd#/PsmCmd Clump Offset Length LbaMid LbaLow LbaBits39To32 Options Status DestClump DestOffset
000E D772 FBB9 6674 9384 FFFF D798 A2E3 0080 BFCA B9E5
通过固件分析、处理,最后硬盘正常认盘,DE镜像,成功恢复客户的工作数据!