ST2000DM001不认盘恢复数据成功案例!
客户:王先生
日期:2017.8.26
硬盘型号:ST2000DM001-9YN164 SN:W1E2CMA6 FW:CC4B 电路板号:100664987
故障现象:硬盘通电正常起转,电脑不识别。
解决方案:收到硬盘后,接到数据恢复工具PC-3000 UDMA Express上,通电检测发现,终端信息如下:
Boot 0x40M
Spin Up
TCC-001E[0x000065B4][0x00006A20][0x00006E8C]
Trans.
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-001E
(P) SATA Reset
MCMainPOR: Start:
Check MCMT Version: Current
MCMainPOR: Non-Init Case
MCMainPOR: EXCEPTION: MCMT PRI copy corrupt
MCMainPOR: MCMT SEC copy valid
Reconstruction: MCMT Reconstruction Start
Max number of MC segments 0A61
Nonvolatile MCMT sequence number 00F96F30
[RSRS] 0005
ProcessRWError -Read- at LBA 0000000000000A3C Sense Code=40000087
InitiateMarkPendingReallocateRequest for disc_lba: 0000000000000A3C!
Reconstruction: Completed 1:
[MCMTWS]
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-001E
LED:00000047 FAddr:FFFFFFFE
LED:00000047 FAddr:FFFFFFFE
这是希捷硬盘比较常见的固件故障,我们处理固件后,硬盘断电再通电正常认盘,DE镜像,成功恢复客户几乎全部的资料。