ST500DM002不认盘恢复数据成功案例!
客户:杨先生
日期:2014.11.11
硬盘型号:ST500DM002-9YN14C SN:Z1D1CZT4 FW:CC4C 电路板:100664987
故障现象:希捷的500G的硬盘,通电不认盘,终端信息如下:
Boot 0x40M
Spin Up
TCC-0017[0x00006A20][0x00006E8C]
Trans.
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-0017
(P) SATA Reset
MCMainPOR: Start:
Check MCMT Version: Current
MCMainPOR: Non-Init Case
MCMainPOR: EXCEPTION: MCMT PRI copy corrupt
MCMainPOR: MCMT SEC copy valid
Reconstruction: MCMT Reconstruction Start
Max number of MC segments 0A61
Nonvolatile MCMT sequence number 00EFD1F5
[RSRS] 0275
ProcessRWError -Read- at LBA 000000000001FEEA Sense Code=40000087
InitiateMarkPendingReallocateRequest for disc_lba: 000000000001FEEA!
Reconstruction: Completed 1:
[MCMTWS]
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-0017
LED:00000047 FAddr:FFFFFFFE
LED:00000047 FAddr:FFFFFFFE
解决方案:接到我们专业的数据恢复工具PC3000 UDMA-E上,硬盘不认盘,进希捷专修程序,处理固件后硬盘正常认盘,最后成功恢复客户几乎所有的工作文档类资料!