ST1000DM003不认盘恢复数据成功案例
客户:咸宁李女士
日期:2014.8.31
硬盘型号:ST1000DM003-9YN162 SN:S1D57VG4 FW:CC4B 电路板:100664987
故障现象:希捷1T硬盘,通电不认盘,终端信息如下:
Boot 0x40M
Spin Up
TCC-001B[0x00026F7C][0x000273E8][0x00027854]
Trans.
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-001B
(P) SATA Reset
MCMainPOR: Start:
Check MCMT Version: Current
MCMainPOR: Non-Init Case
MCMainPOR: EXCEPTION: MCMT PRI copy corrupt
MCMainPOR: MCMT SEC copy valid
Reconstruction: MCMT Reconstruction Start
Max number of MC segments 0A61
Nonvolatile MCMT sequence number 00CE85F1
[RSRS] 0809
ProcessRWError -Read- at LBA 0000000000067F73 Sense Code=40000087
InitiateMarkPendingReallocateRequest for disc_lba: 0000000000067F73!
Reconstruction: EXCEPTION: Seg Read Fail: Status = 0000
Continuing after error
Reconstruction: Completed 1:
[MCMTWS]
Rst 0x40M
MC Internal LPC Process
Spin Up
TCC-001B
LED:00000047 FAddr:FFFFFFFE
解决方案:从终端信息可以判断硬盘是固件问题,接上PC3000 UDMA,通电进专修程序,处理好固件后,硬盘正常认盘,恢复出客户需要的几乎全部数据!