ST500DM002通电终端LED报错恢复成功案例

2020/7/22 9:26:27 次浏览 分类:同行数据恢复案例

           ST500DM002不认盘恢复数据成功案例


客户:广州一数据恢复中心

日期:2020.6.26

硬盘型号:ST500DM002-1SB10A    SN:CC43    FW:W9A1D4H0    电路板:100774000

故障现象:希捷500G三角板台式机硬盘,通电不认盘,同行终端观察,通电后报LED错误,更换电路板更换磁头故障依旧。

解决方案:收到硬盘后据恢复工PC-3000 UDMA Express上,通电硬盘不认盘,终端信息如下:

Trans
Rst 0x20M Thermistor Temp 001C
 SIM Error 1002 LBA 0000000000045D8C FD FCFFF3FF
 RW Error 04440081
 SIM Error 1002 LBA 0000000000046B0F FD FCFFF3FF
 RW Error 04440081
2Sync:01 0E
2Sync:01 0E
2Sync:01 0E
(P) SATA Reset

 SIM Error 1002 LBA 000000000003E179 FD FC38B30A
 RW Error 04440081
 SimErrorCode = 00001002, RWErrorCode = 04440081
 SIM Error 1002 LBA 000000000003E179 FD FC38B30A
 RW Error 04440081
 SimErrorCode = 00001002, RWErrorCode = 04440081
 SIM Error 1002 LBA 000000000003E179 FD FC38B30A
 RW Error 04440081
 SimErrorCode = 00001002, RWErrorCode = 04440081
The Registry is corrupt.

LED:0x000000BD FAddr:0x00006454

Rst 0x20M Thermistor Temp 001C
 SIM Error 1002 LBA 0000000000045D8C FD FCFFF3FF
 RW Error 04440081
 SIM Error 1002 LBA 0000000000046B0F FD FCFFF3FF
 RW Error 04440081
 SIM Error 1002 LBA 000000000004655F FD FCFFF3FF
 RW Error 04440081
LED:0x000000BD FAddr:0x00006454

LED:0x000000BD FAddr:0x00006454
热交换之后,处理固件问题,断电通电,硬盘正常认盘,DE镜像,完美恢复出硬盘内几乎全部数据! 




相关资讯

共0条评论网友评论

    暂无评论,快来抢沙发吧!