客户:广州一数据恢复中心
日期:2020.6.26
硬盘型号:ST500DM002-1SB10A SN:CC43 FW:W9A1D4H0 电路板:100774000
故障现象:希捷500G三角板台式机硬盘,通电不认盘,同行终端观察,通电后报LED错误,更换电路板更换磁头故障依旧。
解决方案:收到硬盘后,接到数据恢复工具PC-3000 UDMA Express上,通电硬盘不认盘,终端信息如下:
Trans
Rst 0x20M Thermistor Temp 001C
SIM Error 1002 LBA 0000000000045D8C FD FCFFF3FF
RW Error 04440081
SIM Error 1002 LBA 0000000000046B0F FD FCFFF3FF
RW Error 04440081
2Sync:01 0E
2Sync:01 0E
2Sync:01 0E
(P) SATA Reset
SIM Error 1002 LBA 000000000003E179 FD FC38B30A
RW Error 04440081
SimErrorCode = 00001002, RWErrorCode = 04440081
SIM Error 1002 LBA 000000000003E179 FD FC38B30A
RW Error 04440081
SimErrorCode = 00001002, RWErrorCode = 04440081
SIM Error 1002 LBA 000000000003E179 FD FC38B30A
RW Error 04440081
SimErrorCode = 00001002, RWErrorCode = 04440081
The Registry is corrupt.
LED:0x000000BD FAddr:0x00006454
Rst 0x20M Thermistor Temp 001C
SIM Error 1002 LBA 0000000000045D8C FD FCFFF3FF
RW Error 04440081
SIM Error 1002 LBA 0000000000046B0F FD FCFFF3FF
RW Error 04440081
SIM Error 1002 LBA 000000000004655F FD FCFFF3FF
RW Error 04440081
LED:0x000000BD FAddr:0x00006454
LED:0x000000BD FAddr:0x00006454
热交换之后,处理固件问题,断电通电,硬盘正常认盘,DE镜像,完美恢复出硬盘内几乎全部数据!