ST1000LM035通电终端报LED恢复成功案例

2020/4/30 9:48:24 次浏览 分类:硬盘软硬件故障恢复案例

          ST1000LM035通电报LED恢复成功案例


客户:科技王一经销商

日期:2020.4.11

硬盘型号:ST1000LM035-1RK172     SN:WDESWJQ0   FW:SDM2   电路板号100809471

故障现象:希捷1000G超薄原装移动硬盘,通电不认盘。

解决方案:收到硬盘后我们据恢复工具PC-3000 UDMA Express上,通电终端信息如下 :

Boot 0x80M
Rst 0x80M
T:0x000A 0x1633B0F1Srv DETCR init 0x0000
FTU
(P) SATA Reset

RAW OFF
 PASS
(DOS Table) Worst Count: 00000CA0 At SU: 00005232 NT: 00000000 OT: 00000004
MSP213
(MC POR Duration): 0000000040
Send Status: COMRESET seen
CSpd= 6Gbps
DSC
(DOS) SU:0003ACBB Ct:00000AA6 Adjusted BRO: 000956C734 - 000956E529
Update Mask - 000000004AB64F38 - 00000008 - 00
Starting LBA of RW Request=000956C734  Length=00001DF6
ProcessRWError -Read-   at LBA 000956CA01  Sense Code=43110081
Common path start quit now ProcessRC: 00000000,00000000SkipLen: 00000000ReadContinuous: 0956C982,0000024EUnrecovSectorCount:001A,01B3NumUDEs: 0000001A,00000064,000001B3Passed: 00000080,000000EC,00000213Out: 
PrgF
LED:0x000000BD FAddr:0x0000780F

LED:0x000000BD FAddr:0x0000780F

LED:0x000000BD FAddr:0x0000780F

修复固件问题后,硬盘再断电通电,正常认盘,镜像,成功恢复硬盘内几乎全部数据!